Shopping security
The B&K Precision DAS220-BAT is a portable 10-channel data recorder that measures and records parameters commonly found in process applications, including voltage, temperature, current, resistance, frequency, and pulse. It integrates 10 universal analog channels with convenient screw input terminals, and results are viewed graphically and numerically on a 10-inch color touchscreen and saved to internal memory or external USB memory. The instrument was developed by B&K Precision's French subsidiary Sefram, which specializes in the design and manufacture of data acquisition instruments and field strength meters.
The DAS220-BAT supports temperature logging with thermocouples and platinum resistance temperature sensors, voltage measurements down to the ±0.5 mV range, 4-20 mA current loop measurements, and frequency, pulse totalization, and pulse rotation measurements that can be expressed in RPM. A data recorder of this type captures measured values over time so an engineer can track how a process behaves and review the logged record afterward.
ValueTronics stocks and holds its own inventory in a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois.
The DAS220-BAT was developed by Sefram, B&K Precision's French subsidiary, which specializes in the design and manufacture of data acquisition instruments, field strength meters, and other test and measurement instruments.
| Specification | Value |
|---|---|
| Analog Channels | |
| Analog Input Channels | 10 integrated channels |
| DC Voltage | |
| Ranges | ± (0.5, 1, 2.5, 5, 10, 25, 50, 100) mV; ± (0.5, 1, 2.5, 5, 10, 25, 50, 100) V |
| Maximum input Voltage | 100 V DC |
| Accuracy | 0.1% of the full scale ±10 µV |
| Temperature with Thermocouples (Cold junction compensation: ±0.5 °C) | |
| Type J | -210 °C to 1200 °C |
| Type K | -250 °C to 1370 °C |
| Type T | -200 °C to 400 °C |
| Type S | -50 °C to 1760 °C |
| Type B | 200 °C to 1820 °C |
| Type E | -250 °C to 1000 °C |
| Type N | -250 °C to 1300 °C |
| Type C | 0 °C to 2320 °C |
| Type L | -200 °C to 900 °C |
| Temperature with Pt100 and Pt1000 | |
| Current | 1 mA (Pt100), 100 µA (Pt1000) |
| Range | -200 °C to 850 °C |
| Measurements | 2 and 3 wires |
| Accuracy (at 20 °C) | 0.3 °C ±0.1% of reading |
| Compensated Resistance (2 wires) | 30 Ω max. |
| Compensated Resistance (3 wires) | 50 Ω max. |
| Resistance | |
| Ranges | 1 kΩ and 10 kΩ |
| Accuracy | 1 Ω (range 1 kΩ) and 10 Ω (range 10 kΩ) |
| Acquisition System | |
| Resolution | 16 bit |
| Acquisition System | Scan, one sample per channel |
| Sampling Interval (V >50 mV) | 1 ms to 20 min |
| Sampling Interval (V ≤50 mV, thermocouples and Pt100 / Pt1000) | 2 ms to 20 min |
| Trigger | Date, delay, threshold, combination of thresholds (and/or), word on logic channels (and, or, slope, level) |
| Pre-trigger | Variable from 0 to 100k samples |
| Logic Input/Output | |
| Number of Channels | 12 |
| Maximum Permitted Voltage | 24 V Cat I |
| Input Impedance | 4.7 kΩ |
| Sampling Rate | 1 ms max. |
| Timing Input | |
| Number of Channels | 4 (K1 to K4) |
| Maximum Permitted Voltage | 24 V Cat I |
| Input impedance | 4.7 kΩ |
| Sampling Rate | 1 ms max. |
| Pulse Counter | 0 to 10 Million, accuracy 1 ppm |
| Frequency Measurement | 1 Hz to 10 kHz, accuracy 0.1% |
| PWM Measurement | 100 Hz to 2 kHz, accuracy 0.1% |
| Alarm Output | |
| Number of Channels | 4 Alarms (A, B, C, D) |
| Output Level | 0 to 5 V |
| General | |
| Internal Flash Drive Size | 32 GB |
| Maximum File Size | 2 GB |
| Operating Temperature | 0 °C to 40 °C, 80% RH (no condensation) |
| Storage Temperature | -20 °C to 60 °C |
| Display | 10” TFT touchscreen LCD, backlit, 1024 x 600 dots |
| Power Supply | 15 V / 4 A max with main adapter (100 / 240 VAC) |
| Interfaces | 2 x USB host, LAN (10/100 base-T with RJ45 socket) |
| Battery | Non removable, Lithium-ion |
| Typical Battery Life | 15 hours with standby mode, 10 hours without stand-by mode |
| Safety | Cat I 100 V, according to IEC61010-1 |
| Weight | 3.3 lbs (1.5 kg) |
| Dimensions (W x H x D) | 2.6” x 11.7” x 6.9” (66 x 298 x 176 mm) |
| Warranty | Two Years |
Important: Maximum input voltage: 100 V DC. Safety rating: Cat I 100 V, according to IEC61010-1.
Important: 4 to 20 mA current loop measurements require the optional 4 to 20 mA / 50 Ω shunt (P/N 902406500), which is not included with the base unit; the 50 Ω shunt can be used on any channel to measure, display, and record the output from 4 to 20 mA current loop sensors.
Important: Resistance and current measurement (to ±100 V, resistance to 10 kΩ) is supported with the optional shunt input-terminal block.
This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.